Toten 42U Server Rack 600x800x2000
55,000.00৳
Toten 42U Server Rack 600x800x2000 is the deep-chassis professional enclosure for high-density IT deployments in Bangladesh. With an 800 mm internal depth and 1000 kg static load capacity, this rack accommodates the largest rack-mount servers, dual-controller storage arrays, and oversized networking equipment that shallower 600 mm racks cannot fit.
- 42U rack space — 800 mm deep chassis fits full-depth servers, storage arrays, UPS
- 1000 kg load capacity — cold-rolled SPCC steel, built for maximum-density deployments
- ≥60% perforated doors — lockable front & rear for airflow and physical security
- EIA-310 19-inch standard — universal compatibility with Dell, HPE, Cisco, Lenovo, Supermicro
- Adjustable square-hole rails — fits 1U to 10U rack-mount equipment
- Casters + leveling feet included
- 1-Year manufacturer warranty
In stock in Dhaka — delivery available across Bangladesh.
Call For Best Price 01731605422 (WhatsApp)
Description
Toten 42U Server Rack 600x800x2000 — Deep-Chassis Enclosure for High-Density IT in Bangladesh
When your infrastructure demands more than a standard 600 mm depth can offer — deeper servers, dual-arm cable managers, large rack-mount UPS units, or dense storage arrays — the Toten 42U Server Rack 600x800x2000 is the professional answer. The extra 200 mm of internal depth is not a cosmetic upgrade; it is the difference between a rack that fits your equipment cleanly and one that forces compromise.
At 42U of usable space inside an 800 mm deep enclosure, this rack is the standard choice for ISPs, colocation facilities, dense corporate data centers, and high-performance computing environments across Dhaka, Chittagong, Sylhet, and beyond. Current price: ৳55,000, in stock in Dhaka.
Toten 42U Server Rack 600x800x2000 — Full Specifications
| Specification | Details |
|---|---|
| Brand | Toten |
| Model | 42U Deep-Chassis Server Rack Enclosure |
| Rack Units | 42U |
| External Width | 600 mm |
| External Depth | 800 mm |
| External Height | 2000 mm (~2 meters) |
| Internal Mounting Width | 19 inches (EIA-310 standard) |
| Internal Usable Depth | ~750 mm (after door clearance) |
| Frame Material | Cold-rolled SPCC steel |
| Static Load Capacity | 1000 kg |
| Door Type | Perforated front and rear (≥60% perforation rate), lockable |
| Side Panels | Removable, lockable steel panels |
| Mounting Rails | Adjustable, square-hole, 19-inch EIA-310 |
| Cable Entry | Top, bottom, and rear cable management ports |
| Finish | Powder-coated RAL 9005 matte black |
| Ventilation | ≥60% high-perforation rate, front-to-rear airflow |
| Mobility | 4× heavy-duty locking casters + adjustable leveling feet |
| Grounding | Built-in grounding point |
| Assembly | Flat-pack, tool-assisted modular |
| Warranty | 1 Year Manufacturer Warranty |
| Price in Bangladesh | ৳55,000 |
600×800 vs 600×600 — Which Rack Depth Do You Need?
Choosing between 600 mm and 800 mm depth is one of the most common questions IT managers face when specifying server racks in Bangladesh. Here is a practical guide:
| Factor | 600x600x2000 (Toten) | 600x800x2000 (This Rack) |
|---|---|---|
| Internal usable depth | ~550 mm | ~750 mm |
| Full-depth servers (HPE DL380, Dell R740) | Tight — may require front-rail-only mounting | Fits cleanly with cable clearance |
| Dual-arm cable managers | Insufficient depth | Full clearance |
| Storage arrays (Dell MD, HPE MSA, NetApp) | Most arrays require 700 mm+ | Recommended choice |
| Rack UPS (APC SURT, Eaton 9PX) | Marginal — check UPS depth spec | Fits all standard rack UPS models |
| Static load capacity | 800 kg | 1000 kg |
| Floor space footprint | Smaller — better for space-limited rooms | Larger — requires 800 mm rack row depth |
| Typical use case | Office IT, SME server rooms, edge sites | Data centers, ISP PoPs, colocation, HPC |
| Price | ৳48,000 | ৳55,000 |
Rule of thumb: If any of your current or planned equipment has a chassis depth greater than 500 mm, or if you plan to use dual-arm cable managers, rack-mount storage, or large UPS units — choose the 800 mm depth. The extra cost is minimal compared to discovering a fit problem after installation.
42U Rack Capacity Guide — How Much Fits?
The 42U rack gives you 42 rack units of mounting space. With 800 mm internal depth, even deep equipment mounts with full rear-cable clearance:
| Equipment | Height | Chassis Depth | Fits in 600×800? |
|---|---|---|---|
| Dell PowerEdge R750 (2U) | 2U | 752 mm | Yes |
| HPE ProLiant DL380 Gen10 (2U) | 2U | 718 mm | Yes |
| Dell PowerEdge R940 (2U) | 2U | 755 mm | Yes |
| HPE MSA 2060 Storage Array (2U) | 2U | 538 mm | Yes |
| APC SURT3000RMXLI UPS (3U) | 3U | 660 mm | Yes |
| Cisco Catalyst 9300 Switch (1U) | 1U | 445 mm | Yes |
| 24-port patch panel (1U) | 1U | Standard | Yes |
| Dual-arm cable manager (1U–2U) | 1U–2U | Requires 700 mm+ | Yes (not possible in 600 mm rack) |
Compatible Equipment — What This Rack Is Built For
The Toten 42U 600x800x2000 follows the EIA-310 19-inch standard and its 800 mm depth makes it the correct choice for:
Full-Depth Servers
- Dell PowerEdge R750, R740, R940, R7525, R6525
- HPE ProLiant DL380 Gen10/Gen11, DL560, DL580
- Lenovo ThinkSystem SR650, SR850, SR950
- Supermicro 2U and 4U storage-optimized platforms
- IBM Power9 and Power10 rack servers
Storage Arrays
- Dell EMC PowerVault ME4 / ME5 series
- HPE MSA 2060 / 2062 storage arrays
- Synology RackStation RS-series (RS3621xs+, RS4021xs+)
- QNAP TS-h series rack NAS
- NetApp FAS2750 and AFF series
Networking Equipment
- Cisco Catalyst 9300, 9400, Nexus 5000/7000 series
- Huawei CloudEngine CE6870, CE8850
- Juniper EX4300, QFX series
- Arista 7050 / 7060 series switches
- MikroTik CCR2004 and CCR2116 routers
Power & Accessories
- APC Smart-UPS RT SURT series (rack-mount UPS)
- Eaton 9PX and 5PX rack UPS
- Socomec NeTYS RT rack UPS
- Dual-arm cable management arms (1U–2U)
- Rack PDU — 1U horizontal or vertical 0U
- Blanking panels, tool-less or screwed (1U)
Why Choose This Rack for Your Bangladesh IT Deployment?
1. The Depth That Full-Density Deployments Require
The most common rack specification mistake in Bangladesh data center projects is underestimating equipment depth. Modern high-performance servers — the Dell R750, HPE DL380, storage arrays — have chassis depths of 700–760 mm. In a 600 mm rack, this leaves zero room for cabling at the rear. The Toten 600x800x2000 provides ~750 mm of usable internal depth after door clearance, ensuring every piece of equipment mounts correctly with clean cable runs behind it.
2. 1000 kg Load — Built for Maximum-Density Racks
High-density deployments are heavy. A fully populated 42U rack with 2U servers every slot, plus a rack UPS and storage array, can approach 700–900 kg. The Toten 600×800’s 1000 kg static load rating — 25% higher than the standard 800 kg shallow model — provides the safety margin that serious deployments require. The cold-rolled SPCC steel frame maintains structural integrity without flex under maximum load.
3. Airflow at Scale — Critical for Bangladesh’s Climate
Bangladesh’s ambient temperatures regularly reach 32–38°C in Dhaka and Chittagong. In a server room or data center, improper airflow in deep, dense racks creates thermal hotspots that degrade equipment lifespan and trigger unexpected shutdowns. The Toten 600×800’s ≥60% perforated door design maintains the front-to-rear airflow path even at full equipment density — critical for hot-aisle/cold-aisle configurations in Bangladeshi data centers.
4. Physical Security for Enterprise Compliance
For banks, financial institutions, hospitals, government agencies, and ISPs across Bangladesh, physical access control is a compliance requirement — not optional. The lockable front door, lockable rear door, and removable lockable side panels ensure only authorized personnel access your hardware, satisfying internal security audits and regulatory inspection requirements.
5. Enterprise Quality at Bangladesh’s Market Price
European and American deep-chassis racks of equivalent specification routinely cost 2–4× more when imported. At ৳55,000, the Toten 42U 600x800x2000 delivers a 1000 kg rated, 800 mm deep, fully lockable professional enclosure at a price point viable for both single-rack deployments and large multi-rack data center rollouts.
Who Uses This Rack — Bangladesh Deployment Scenarios
- ISP backbone and Point-of-Presence (PoP) sites: Deep chassis handles large routing platforms, OTN/DWDM equipment, and deep-chassis DSLAM/OLT hardware.
- Colocation data centers (Dhaka, Chittagong): Standard choice for co-lo providers who must accommodate any customer equipment, including full-depth enterprise servers.
- Banking and financial institutions: Core banking servers, storage arrays, and disaster recovery infrastructure in secure, compliant enclosures.
- Hospitals and healthcare IT: PACS imaging storage (requires large-capacity NAS), HIMS servers, and medical data backup systems.
- Garments and manufacturing ERP: High-availability ERP and MES server infrastructure requiring dense, reliable enclosures.
- Universities and research institutions: HPC clusters, research data storage, and dense virtualization hosts.
- Government data centers: Secure enclosures for sovereign data infrastructure requiring physical access controls.
Frequently Asked Questions — Toten 42U Server Rack 600x800x2000
What is the price of the Toten 42U Server Rack 600x800x2000 in Bangladesh?
The Toten 42U Server Rack 600x800x2000 is priced at ৳55,000 in Bangladesh. This includes the rack enclosure, casters, leveling feet, and mounting rail hardware. Contact us for bulk pricing on multi-rack orders.
What is the difference between the 600×600 and 600×800 Toten 42U rack?
The key differences are depth and load capacity. The 600×800 provides ~750 mm of usable internal depth (vs ~550 mm in the 600×600), making it suitable for full-depth servers, dual-arm cable managers, and storage arrays. The load capacity is also higher at 1000 kg vs 800 kg. The 600×800 is recommended whenever any equipment chassis depth exceeds 500 mm.
What is the maximum load capacity of this rack?
The Toten 42U 600x800x2000 has a 1000 kg static load capacity — 25% higher than the standard shallow model. This accommodates fully populated high-density configurations including multiple full-depth servers, storage arrays, and a rack-mount UPS.
Will the Dell PowerEdge R750 or HPE DL380 Gen10 fit in this rack?
Yes. The Dell PowerEdge R750 has a chassis depth of 752 mm and the HPE ProLiant DL380 Gen10 is 718 mm — both fit in the Toten 600x800x2000 with ~750 mm of usable internal depth, leaving adequate rear cable clearance. These servers cannot be cleanly installed in a 600×600 rack.
Is the rack compatible with standard 19-inch equipment?
Yes. It follows the EIA-310 19-inch standard, making it universally compatible with all rack-mount servers, switches, patch panels, KVM units, and PDUs from any major brand.
Does it come with casters and leveling feet?
Yes. Both heavy-duty locking casters for repositioning and adjustable leveling feet for stable floor installation are included.
Is delivery available outside Dhaka?
Yes — we deliver to Dhaka, Chittagong, Sylhet, Rajshahi, Khulna, Cumilla, and all major districts across Bangladesh. Contact us for freight timelines outside Dhaka.
How is the rack shipped?
The rack ships as a flat-pack modular assembly, reducing damage risk in transit and allowing movement through standard doorways before assembly. Two-person assembly typically takes 60–90 minutes with standard tools.
Delivery, Stock & Purchasing Information
The Toten 42U Server Rack 600x800x2000 is available in stock in Dhaka. We supply IT infrastructure equipment to ISPs, banks, hospitals, government agencies, colocation providers, universities, and enterprise businesses across Bangladesh.
- In stock — ready for immediate dispatch from Dhaka
- Nationwide delivery — Dhaka, Chittagong, Sylhet, and all districts
- Corporate invoicing — LC, bank transfer, and purchase orders accepted
- Technical support — deployment guidance for large or multi-rack projects
- Bulk pricing — contact us for quotes on 3+ units
- Also available: Toten 42U 600x600x2000 at ৳48,000 for standard-depth deployments
At Telecare System, we deliver quickly, safely, and affordably across Bangladesh. After placing your order, you’ll receive a confirmation email, and our support team will follow up with a call to assist you.
Delivery Options:
- Within Dhaka: 1-2 business days, BDT 150.
- Outside Dhaka: 2-3 business days, BDT 150.
For any questions, please contact us—we’re here to help!
Toten 6U Server Rack
Toten 4U Server Rack
Toten 15U Wall Mount Network Cabinet
Toten 15U Server Rack Key Features
Type: Wall Mount Network Cabinet Cabinet size (W*D*H): 600*600*800mm- 4PCS mounting profiles
- Tempered glass Front Door+1PC Shelf
- 2PC plastic Fan(EU) +1PC 6- universal socket EU Plastic PDU
- Thickess (mm) others/mounting profile : 0.8/1.5mm
We are Toten Server Rack Importer In Bangladesh
Toten 32U Server Rack
Toten 22U Server Rack
Toten 9U Server Rack
RELATED PRODUCTS
Toten 22U Server Rack
Toten 9U 600 x 600mm x 500 Server Rack
Toten 22U Server Rack 600x800x1200
Toten 32U Server Rack 600x800x1600
Toten 18U Floor Stand Server Rack
Toten 18U Floor Stand Server Rack Key Features
Cabinet size (W*D*H): 600*600*1000mm- 4PCS mounting profiles
- Tempered glass Front Door+1PC Shelf
- 2PC plastic Fan(EU) +1PC 6- universal socket EU Plastic PDU
- Thickess (mm) others/mounting profile : 0.8/1.5mm
We are Toten Server Rack Importer In Bangladesh
Toten 15U Wall Mount Network Cabinet
Toten 15U Server Rack Key Features
Type: Wall Mount Network Cabinet Cabinet size (W*D*H): 600*600*800mm- 4PCS mounting profiles
- Tempered glass Front Door+1PC Shelf
- 2PC plastic Fan(EU) +1PC 6- universal socket EU Plastic PDU
- Thickess (mm) others/mounting profile : 0.8/1.5mm
We are Toten Server Rack Importer In Bangladesh
People Also Purchased
Toten 9U 600 x 600mm x 500 Server Rack
Toten 6U Server Rack
Toten 42U Server Rack
Toten 42U Server Rack 600x800x2000
- 42U rack space — 800 mm deep chassis fits full-depth servers, storage arrays, UPS
- 1000 kg load capacity — cold-rolled SPCC steel, built for maximum-density deployments
- ≥60% perforated doors — lockable front & rear for airflow and physical security
- EIA-310 19-inch standard — universal compatibility with Dell, HPE, Cisco, Lenovo, Supermicro
- Adjustable square-hole rails — fits 1U to 10U rack-mount equipment
- Casters + leveling feet included
- 1-Year manufacturer warranty
Toten 9U 600 x 450mm x 500 Server Rack
Toten 15U Wall Mount Network Cabinet
Toten 15U Server Rack Key Features
Type: Wall Mount Network Cabinet Cabinet size (W*D*H): 600*600*800mm- 4PCS mounting profiles
- Tempered glass Front Door+1PC Shelf
- 2PC plastic Fan(EU) +1PC 6- universal socket EU Plastic PDU
- Thickess (mm) others/mounting profile : 0.8/1.5mm